News

Water Cooled Condenser, Shell & Tube Type, Cooling Water Circuit & Water Quality Requirement

  • Category:
  • Browse number: ...
  • Release time: 2026-10-31

Water Cooled Condenser, Shell & Tube Type, Cooling Water Circuit & Water Quality Requirement

Shell and tube water cooled condenser: high pressure refrigerant gas outside tubes, cooling water flows inside copper tubes for heat exchange. Heat transfer efficiency is higher than air cooled type, stable condensing temperature, suitable for large rack unit and high heat load. Cooling water takes heat away and flows to cooling tower for re-cooling; water system needs water pump, pipeline, water treatment. Water quality control is critical: high hardness water causes scale attached on inner tube wall, heat transfer capacity drops sharply. Xiteliduo shell and tube condenser adopts seamless copper tube, can be matched with open type or closed cooling tower. Water flow rate must keep within design range; insufficient water flow leads to high condensing pressure; excessive flow wastes pump power. Water side chemical cleaning is required periodically; scale, slime and algae are hard to remove once thickened. Winter low ambient region needs water circuit anti-freeze: drain water, add antifreeze or install tracing heating cable. Water cooled system has more auxiliary equipment, higher initial investment and maintenance cost than air cooled solution. Refrigeration maintenance & repair company monitors water inlet/outlet temperature difference to judge fouling degree.

FAQ

  1. What is the mainstream structure of water cooled condenser? Shell and tube type.
  2. Which medium flows inside the tube? Cooling water.
  3. What is the advantage of water cooled condenser? Higher heat exchange efficiency, stable condensing pressure.
  4. What is the main hazard of hard cooling water? Scale formation on inner tube wall.
  5. What equipment is needed to cooperate with water cooled condenser? Cooling tower and water circulation pump.
  6. How to judge water side fouling? Water temperature difference becomes smaller than design value.
  7. What protection for water circuit in cold winter? Drain water, antifreeze liquid or heat tracing.
  8. What is the disadvantage of water cooled system? Extra water system investment and maintenance work.
url: https://www.xtldcool.com/news/843.html

Obtain product customization plans online

Please fill in the requirements in the box below, and you will be able to obtain it for free.

Consulting Hotline

+86-18157593311

Xiteliduo & Chuanli

China Source Factory of R32 Semi-Hermetic Piston Compressor & Custom Turnkey Industrial Refrigeration System. Self-developed compressor + complete refrigeration solution, stable performance for tropical & ultra-low temperature working conditions.

connect us

Technical Services: +86-575-83665888;83068555 
Compressor Hotline: +86-18157593311 
Electric Heating Tube Hotline: +86-13857577938 
Email: helenliu1983xtld@gmail.com
Electric Heating Tube Factory: No. 150, Donghu Village, Ganlin Town, Shengzhou City, Shaoxing City 
Compressor Factory: No. 679, Dongguo Economic Development Zone, Shengzhou City, Shaoxing City

Copyright © 2026 Zhejiang Xitelidu Environmental Technology Co., Ltd. & Shengchuanli Environmental Technology Co., Ltd. All Rights Reserved.